العنوان
Effect of design parameters on column shortening in tall concrete buildings /
الناشر
Eslam Abdelnabi Ahmed Hemayed ,
المؤلف
Eslam Abdelnabi Ahmed Hemayed
تاريخ النشر
2015
عدد الصفحات
278 P. :
الفهرس
Only 14 pages are availabe for public view

from 305

from 305

Abstract

The In tall concrete buildings, the vertical elements: columns, shear walls, and cores undergo elastic shortening and time dependant axial shortening caused by creep and shrinkage. In this study, a computer program was developed and verified to calculate column axial shortening based on the ACI 209R - 92 model. The developed program was used to investigate the effects of different design parameters on column shortening. The results showed that increasing the column design reinforcement ratio increases both before - floor - casting and after - floor - casting column shortening. In particular, compared to 1% ratio, increasing the column reinforcement ratio to 2%, 3%, and 4% increases the before - floor - casting column shortening by 5% to 11%, 9% to 22%, and 13% to 32%, respectively. Besides, compared to 1% ratio, increasing the column reinforcement ratio to 2%, 3%, and 4% increases the after-floor-casting column shortening by 7% to 9%, 14% to 17%, and 20% to 27%, respectively. However, the effect of column aspect ratio has a minor effect on column shortening. Nevertheless, increasing the rate of construction results in a significant increase in the after - floor - casting shortening but greatly reduces the before - floor - casting shortening of columns. In addition, the results showed that increasing the design concrete strength increases the column shortening