Evaluation of the effect of customized
V pattern plate fixation versus a conventional superior –inferior miniplates fixation of mandibular angle fracture :
المؤلف
Hiba Obad Saleh Saeed,
هيئة الاعداد
باحث / Hiba Obad Saleh Saeed
مشرف / Basma Gamal Moussa
مشرف / Khaled Amr Salah Eddin
مشرف / Ahmed Mohammed Salah
مشرف / Samer Abduljabar Noman
الموضوع
Oral and Maxillofacial surgery.
تاريخ النشر
2020.
عدد الصفحات
140 p. :
اللغة
الإنجليزية
الدرجة
الدكتوراه
التخصص
Dentistry (miscellaneous)
تاريخ الإجازة
1/1/2020
مكان الإجازة
جامعة القاهرة - الفم والأسنان - Oral and Maxillofacial surgery
الفهرس
Only 14 pages are availabe for public view

from 143

from 143

Abstract

Aim: To evaluate the effect of customized V pattern plate fixation versus a conventional
superior-inferior mini plates fixation of mandibular angle fracture
Methodology: This work was conducted between January 2019 to January 2020 . A total of
26 pateients with unilateral unfavorable mandibular angle fractures were selected from the
outpatient clinic of Oral& Maxillofacial Surgery Department, Faculty of Dentistry-Cairo
University and Ahmed Maher Teaching Hospital to participate in this study.
Results: The results showed that there was a statistical difference between study group and
control group regarding the post-operative occlusion and bone density along the fracture line.
There was no statistical difference (p value > 0.05) in postoperative panoramic radiographs
that were taken within the postoperative first week. There was a statistically significant of
maximal mouth opening in both groups in postoperative first week and first month. However
there was no statistically significant of maximal mouth opening in the postoperative third
and sixth months in both groups in which maximal mouth opening became normal.
Conclusions: A customized V pattern plate design as comparble to the conventional superior
-inferior miniplates is an appropriate plate structure for unfavorable mandibular angle
fracture,it ensures a proper alingment of the fracture with plate fixation and adequate
postoperative radiographical results . It reduces the chance of post operatrive complications