Abstract Ten patients underwent segmental mandibular resection divided into two groups (control group) 5 patients received immediate segmental autogenous block bone grafts from anterior iliac crest with Titanium plate and second group is (study group) 5 patient receiving immediate segmental reconstruction with particulate bone grafts from anterior iliac crest with titanium mesh. Pre-operative CT Scans was done for all patients and Computer software used to restore mandibular and facial symmetry by mirror imaging the healthy side, design for template to guide the osteotomy margins during surgical procedure and another one for pre- bend reconstructive plate that is contoured to the margins of native mandible after resection. The three dimensional modelling techniques was showed more accurate and fit during management of surgical procedure for immediate segmental mandibular reconstruction |